< Previous4 30 CENTURION LiFeP0 4 Lithium-Iron Phosphate 1000VA | 2000VA | 3000VA ENHANCED UPS PROTECTION | CENTURION L i F e PO 4 The Centurion LiFePO 4 features true online double conversion. As our highest single phase power density UPS, this sophisticated range will provide the most comprehensive protection for mission critical devices such as sensitive networks, computers, servers, telecom applications, as well as industrial applications. Meticulously developed by PowerShield engineers to be a world leading technology UPS, the Centurion RT addresses absolutely all requirements and features as has been demanded by the sophisticated Australian power consumer and hence stands in a class of its own, as a world leading UPS technology. EXCEPTIONAL SURGE PROTECTION Offering the best surge protection in its class to protect against damaging surges. RACK/TOWER DESIGN The Centurion RT can be easily installed as a floor-standing tower or in a 19-inch rack. PROGRAMMABLE OUTLETS This UPS comes with programmable power management outlets allowing the user to control the load segments, thereby extending battery backup times to mission critical devices by shutting down non-critical items. HID COMMUNICATION VIA USB HID can be used for simple management with Windows, Apple, Linux and NAS devices and a large variety of industrial controllers that support HID. HID ensures a safe and orderly shutdown in the event of a prolonged power outage. FEATURES NETGUARD® SOFTWARE COMMUNICATION VIA USB The free, downloadable NetGuard® Software provides complete power monitoring. Parameters such as input/output voltage, remaining battery time & load level are easily viewed. It also ensures a safe and orderly shutdown in the event of a prolonged outage. ECO AND ADVANCED ECO MODE Advanced ECO mode allows the UPS to operate at a very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode. OPTIONAL ACCESSORIES •PSSNMPV4 – SNMP card (option to connect a PSEMD) •PSEMD – Environmental Monitoring, temperature and humidity •PSModbus – Modbus card • PSAS400 – AS400 dry contact card • PSRK – rail kit • PSMBS2k, PSMBS3k – Maintenance Bypass Switches IUMUMPREMIUM PROTECTIONONPROTECTIONONCTION PREMIUM PROTECTION TRUE 5 YEAR WARRANTY EXTENDED BATTERY LIFE Provides double to triple battery life, making it cheaper to run and providing lower total cost of ownership. LIGHTER WEIGHT Batteries are up to one third lighter making installation and battery changes easier to carry out. FASTER RECHARGE 3 times faster recharge rate. HIGHER POWER DENSITY Provides longer runtimes. HIGHER TEMPERATURE TOLERANCE Batteries can operate in environments up to 40ºC without battery degradation. HIGHER PERFORMANCE Advanced LiFePO4 battery management system ensures the utmost efficiency during charging and discharging. SAFETY The chemical composition of LiFePO 4 batteries ensures that they are non- flammable. THE LITHIUM-IRON PHOSPHATE ADVANTAGECENTURION LiFePO 4 MODEL CENTURION RT LiFePO 4 1KVA CENTURION RT LiFePO 4 2KVACENTURION RT LiFePO 4 3KVA Model NumberPSLCERT1000PSLCERT2000PSLCERT3000 Capacity1000VA/900W2000VA/1800W3000VA/2700W TopologyTrue online double-conversion, Pure Sine Wave INPUT Voltage Range Line Loss160Vac / 140Vac / 120 / 110VAC ± 5 % (based on load percentage 100%-80% / 80%-70% / 70%-60% / 60%-0) Low Line Comeback175Vac / 155VAC / 135VAC / 125VAC ± 5 % High Line Transfer300VAC ± 5 % High Line Comeback290VAC ± 5 % Frequency Range 40Hz – 70Hz PhaseSingle phase with ground Power Factor Correction 0.99 @ nominal voltage (100% load) OUTPUT Output Power Factor0.9 Output Voltage (AC Mode)240VAC (Selectable 200/208/220/230/240VAC) Voltage Regulation (Batt. Mode)± 1% Frequency Range (Batt. Mode)50Hz or 60Hz ±1Hz Current Crest Ratio3:1 (max.) Transfer AC Mode to Batt. ModeZero Inverter to Bypass4ms (Typical) Waveform (Batt. Mode)Pure Sine Wave IEC Outlets10A, C13 x 510A, C13 x 5; 16A, C19 x 1 Australian Sockets32 EFFICIENCY ECO Mode (Advanced)96%97%97% Battery Mode87%88%89% BATTERY BatteryLiFePO 4 Typical Recharge Time2 hours Backup Time: 25% Load44 mins44 mins44 mins 50% Load22 mins22 mins22 mins 75% Load14 mins14 mins14 mins 100% Load11 mins11 mins11 mins PROTECTION Full ProtectionOverload, discharge, thermal, short circuit and overcharge protection Surge Protection1872 Joules / 39000 Amps COMMUNICATIONS AND MANAGEMENT InterfaceUSB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact SoftwarePowerShield® NetGuard® software – supports Windows, Linux, Unix and Mac based operating systems HIDSupports Windows, Apple, Linux, NAS and various industrial controllers LCD Display/AlarmUPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators Audible AlarmBattery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload PHYSICAL Dimension (D x W x H) mm 380 x 438 x 88480 x 438 x 88600 x 438 x 88 Weight (kg)10.214.619.7 OPERATING ENVIRONMENT Temperature0–40°C Humidity20–90% (RH Non-condensing) Noise Level< 50dBA @ 1 Meter COMPLIANCE Safety / EMC / RoHSEN62040 -1-1 2003, IEC60950 -1 -1 / EN62040 -2 2006 / Directive 2011/65/EU REAR VIEW Centurion RT LiFePO 4 1000 10Amp IEC input socketCenturion RT LiFePO 4 2000 10Amp IEC input socket Centurion RT LiFePO 4 3000 16Amp IEC input 31 ENHANCED UPS PROTECTION | CENTURION L i F e PO 432 ENHANCED UPS PROTECTION | CENTURION TOWER The Centurion is a True Online Double Conversion UPS designed to provide comprehensive power protection for critical equipment. Versatile software management and hardware options offer the flexibility to build up a power protection solution to fit any application. Meticulously developed by PowerShield engineers to be a world leading technology UPS, the Centurion Tower addresses absolutely all requirements and features as has been demanded by the sophisticated Australian power consumer and hence stands in a class of its own, as a world leading UPS technology. CENTURION TOWER 110V 1000VA | 2000VA | 3000VA IUMUMPREMIUM PROTECTIONONPROTECTIONONCTION PREMIUM PROTECTION TRUE EXCEPTIONAL SURGE PROTECTION Offering the best protection in its class to protect against damaging surges. OUTPUT POWER FACTOR The Centurion Tower is a high-density UPS with output power factor (PF=0.9) to provide higher performance and efficiency to critical applications. INFORMATIVE LCD DISPLAY The front panel LCD display panel is readily viewable and displays all critical and noncritical parameters, including the estimated battery backup time remaining. PROGRAMMABLE OUTLETS This UPS comes with programmable power management outlets allowing the user to control the load segments, thereby extending battery backup times to mission critical devices by shutting down non-critical items. EMERGENCY POWER OFF FUNCTION (EPO) This feature can turn off and isolate the UPS in the event of fires or other emergencies. ADVANCED ECO MODE It has an advanced ECO mode, which allows the UPS to operate at a very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode. HID COMMUNICATION VIA USB HID can be used for simple management with Windows, Apple, Linux and NAS devices and a large variety of industrial controllers that support HID. HID ensures a safe and orderly shutdown in the event of a prolonged power outage. FEATURES NETGUARD SOFTWARE COMMUNICATION VIA USB The free, downloadable NetGuard software provides complete power monitoring. Parameters such as input/output voltage, battery capacity and load level are easily viewed. It also ensures a safe and orderly shutdown in the event of a prolonged outage. BATTERY BANK EXTENSION OPTIONS The Centurion Tower provides the option to increase battery backup time by simply adding additional battery banks. To address the need for fast charging of multiple battery banks, PowerShield engineers have incorporated additional independent internal chargers into the PSCEBB18CH and PSCEBB60CH. OPTIONAL ACCESSORIES •PSSNMPV4 – SNMP card (option to connect a PSEMD) •PSEMD – Environmental Monitoring Device •PSModbus – Modbus card •PSAS400 – AS400 dry contact card •N+X parallel redundancy available for 6K/10K models •Battery Banks – Backup time for all models is easily extended by simply plugging additional battery banks PSCEBB6, PSCEBB12, PSCEBB18CH, PSCEBB40, PSCEBB60CH •External Maintenance Bypass Switches – PSMBS2k, PSMBS3k, PSMBSWPB6k, PSMBSWPB10k33 ENHANCED UPS PROTECTION | CENTURION TOWER CENTURION TOWER SELECTION GUIDE MODEL 1K2K3K Model Number PSCE1000UPSCE2000UPSCE3000U Capacity*1000VA/1000W2000VA/2000W3000VA/3000W INPUT Voltage Range Low Line Transfer80VAC/70VAC/60VAC/55VAC ± 5 % ( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0) Low Line Comeback87VAC/77VAC/67VAC/62VAC ± 5 % High Line Transfer150VAC ± 5 % High Line Comeback145VAC ± 5 % Frequency Range40Hz–70 Hz PhaseSingle phase with ground Power Factor≥ 0.99 @ full load THDi ≤ 5% @ 100–130VAC THDU < 1.6% @ input and full linear load condition> OUTPUT Output voltage100/110/115/120/127VAC AC Voltage Regulation± 1% (Batt. Mode) Frequency Range (Synchronized Range)47–53Hz or 57–63Hz Frequency Range50Hz ± 0.1Hz or 60Hz ± 0.1Hz (Batt. Mode) Current Crest Ratio3:1 Harmonic Distortion≤ 2 % THD (Linear Load) ; 4 % THD (Non-linear Load) Transfer Time AC Mode to Batt. Mode Zero Inverter to Bypass< 4 ms Waveform (Batt. Mode) Pure Sinewave EFFICIENCY AC Mode≥ 89% @ full charged battery≥ 91% @ full charged battery ECO Mode≥ 96% @ full charged battery Battery Mode≥ 88%≥ 90% BATTERY Battery Type12V/9AH Numbers366 Recharge Time3 hours recover to 95% capacity for internal battery@ 2A charging current Charging Current Default 2A, Max. 8A adjustable Charging Voltage 41VDC ± 1%82.1VDC ± 1%82.1VDC ± 1% PHYSICAL C Dimension, D X W X H (mm)397 X 145 X 220421 X 190 X 318 Net Weight (kgs) With battery1323.228.0 Without battery6.69.912.3 ENVIRONMENT Operation Humidity20–95 % RH @ 0–40°C (non-condensing) Noise Level < 50dBA @ 1 Meter (With fan speed control) MANAGEMENT Smart RS-232 or USBSupports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix and MAC Optional SNMPPower management from SNMP manager and web browser Product specifications are subject to change without further notice. Derate capacity to 80% of capacity in frequency converter mode and to 80% when the output voltage is adjusted. For 100/110/115/120/127VAC system, the output power ratings are different based on different input voltage. 34 ENHANCED UPS PROTECTION | CENTURION PRO 3P IUMUMPREMIUM PROTECTIONONPROTECTIONONCTION PREMIUM PROTECTION TRUE VERSATILITY • Adjustable battery numbers •50Hz/60Hz frequency converter mode •Adjustable output voltages •Includes Intelligent Slot, USB and RS232 connections BATTERY BANK EXTENSION OPTIONS •The Centurion Pro provides the option to increase battery backup time by simply adding additional battery banks. •PSCEPBB40, PSCEPBB80 •Up to 30% of the UPS rating for battery recharge •External battery cabinets for 10-year design life batteries available on request OPTIONS •PSSNMPV4 – SNMP card (option to connect a PSEMD) •PSEMD – Environmental Monitoring Device for temperature and humidity •PSModbus – Modbus card •PSAS400 – AS400 dry contact card •PSCSSNMP – Cyber Secure SNMP •Maintenance bypass switches high level protection surge filters CENTURION PRO SERIES 10–80kVA FEATURES HIGH AVAILABILITY •Accepts dual-mains inputs •Generator compatible •Optional N+X parallel redundancy PROTECTION •True online double-conversion •Sophisticated 3-stage extendable charging design for optimized battery performance •Emergency power off function (EPO) •Back feed protection EFFICIENCY • DSP technology guarantees high performance •Output power factor 1.0 •Active power factor correction on all phases •ECO mode operation for energy saving •Using the latest silicon carbide diodes ACTIVE VOICE WARNING Voice notifications alert users error codes LCD DISPLAY The Centurion Pro has an informative colour LCD Display with programmable features. Centurion Pro Three Phase UPS series provides powerful overall protection to your sensitive equipment. Accepting a wide input voltage range for harsh environments, it is the perfect solution for powering a wide range of devices such as servers, data centres, industrial processes, telecommunication and security systems. This small footprint, high power density, double-conversion online UPS has an output power factor of 1.0. It features complete dual mains inputs ranging from 10kVA to 80kVA. It also includes Digital Signal Processing (DSP) technology and active input power factor correction design. This ensures a stable, superior output power quality. Designed in collaboration with PowerShield’s extensive service partner network to address the specific requirements of Oceania. 35 ENHANCED UPS PROTECTION | CENTURION PRO 3P CENTURION PRO SERIES SELECTION GUIDE MODEL10K(L) DUAL20K(L) DUAL30K(L) DUAL40K(L) DUAL60KL DUAL80KL DUAL Model NumberPSCEP10K(L) 3/1 or 3/3 PSCEP20K(L) 3/1 or 3/3 PSCEP30K(L) 3/3 PSCEP40K(L) 3/3 PSCEP60KL 3/3 PSCEP80KL 3/3 Capacity10kVA / 10kW20kVA / 20kW30kVA / 30kW40kVA / 40kW60kVA / 60kW80kVA / 80kW INPUT Voltage Range Low Line Loss110VAC(Ph-N) ± 3% at 50% Load; 176VAC(Ph-N) ± 3% at 100% Load Low Line ComebackLow Line Loss Voltage + 10V High Line Loss300VAC(L-N) ± 3% at 50% Load; 276VAC(L-N) ± 3% at 100% Load High Line ComebackHigh Line Loss Voltage – 10V Frequency Range 46Hz–54Hz @ 50Hz system 56Hz–64Hz @ 60Hz system Phase3 Phase with Neutral Power Factor≥0.99 at 100% Load OUTPUT Phase3 Phase with Neutral Output voltage 360/380/400/415VAC (Ph-Ph) 220/230/240VAC (Ph-N) AC Voltage Regulation± 1% Frequency Range (Synchronized Range) 46Hz–54 Hz @ 50Hz system; 56Hz–64 Hz @ 60Hz system Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz Overload AC mode100%–110%: 60min; 110%–125%: 10min; 125%–150%:1min;>150% : immediately Battery mode100%–110%: 60min; 110%–125%: 10min; 125%–150%:1min;>150% : immediately Current Crest Ratio3:1 MAX Harmonic Distortion≤ 2 % @ 100% Linear Load; ≤ 5 % @ 100% Non-linear Load Transfer Time Line ← → Battery0ms Inverter ← → Bypass0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass) Inverter ← → ECO<10 ms Power Factor0.9 leading to 0.9 lagging EFFICIENCY AC mode95.5% at full load Battery Mode94.5% at full load BATTERY Standard Model Type12V / 9Ah12V / 9Ah12V / 9Ah12V / 9Ah N/A Numbers(20+20)pcs(20+20)pcs(16+16)pcs x 2 strings Recharge Time9 hours recover to 90% capacity Charging Current (max)2.0 A ± 10% (Recommended) 1.0–12.0A (Adjustable) Charging Voltage +/–273 VDC ± 1%+/–218 VDC ± 1% Long-run Model TypeDepending on applications Numbers32–40 (adjustable as ±16, ±18, ±20 ) Charging Current(max.)1.0–12.0A ±10% (Adjustable)2.0–24.0A ±10% (Adjustable) Charging Voltage+/- 13.65 VDC * N ± 1% (N = 16–20) PHYSICAL Standard Model Dimension, D x W x H (mm) 626 x 250 x 826815 x 300 x 1000 N/A Net Weight (kgs)126141230260 Long-run Model Dimension, D x W x H (mm) 626 x 250 x 826815 x 300 x 1000790 x 360 x 1010 Net Weight (kgs)39456571112117 ENVIRONMENT Operation Temperature0–40°C (the battery life will decrease when > 25°C) Operation Relative Humidity< 95% and non-condensing Operation Altitude< 1000m* Acoustic Noise Level < 55dB @ 1 Metre < 58dB @ 1 Metre < 65dB @ 1 Metre < 70dB @ 1 Metre < 70dB @ 1 Metre < 75dB @ 1 Metre MANAGEMENT Smart RS-232 or USBSupports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC Optional SNMPPower management from SNMP manager and web browser STANDARDS SafetyIEC/EN62040-1-1, Performance IEC 62040-3 EMCEMC/EMI/RFI IEC 62040-2 Environmental IEC 62040-4 All specifications are subject to change without notice. Backup times are approximate and variances may occur.REAR VIEWS 36 ENHANCED UPS PROTECTION | PLATINUM MODULAR The Platinum Modular UPS Range is Power Shield’s Premium Range of modular UPSs designed with Australian conditions and high end requirements in mind. The technology is based on a tried and tested platform ensuring reliability and performance. The Platinum Modular is designed to be used in a wide range of applications from data centres to manufacturing, hospitals, military and mining environments to name a few. It provides the best power solution for your critical equipment. REDUNDANCY The modular N+1 / N+X topology provides for an ultra reliable uninterruptible power supply to the load. Modular design is applied in power module, static switch module and battery module. This simplifies maintenance and replacement with low Mean Time To Repair (MTTR). As a result of modular design the Mean Time Between Failure (MTBF) is significantly increased. HIGH SCALABILITY The UPS that grows with your business. As your power demand increases simply add more power modules. Digital Signal Processor (DSP) control provides a reliable solution with high performance. HIGH EFFICIENCY ONLINE DOUBLE CONVERSION The Platinum Modular utilises true online double conversion technology with an efficiency of up to 96%. This significantly reduces overall Total Cost of Ownership (TCO). FEATURES FLEXIBLE BATTERY CONFIGURATION Allows for options of 32, 36 or 40 batteries per string. ADJUSTABLE CHARGING CURRENT Platinum Modular provides maximum 6A for 20kW and 8A for 30kW charging current for every power module and it is adjustable based on requirement. GRAPHIC SCREEN/MIMIC/LCD DISPLAY Designed for easy management, Platinum Modular is equipped with a 5.7” graphic LCD screen. This interactive LCD display gives information on the unit’s operation, alarm and control. The LCD also includes an informative mimic display. Optional 10” colour, touch LCD display (factory fitted). UNITY OUTPUT POWER FACTOR Platinum Modular delivers unity output power (kVA=kW) providing the maximum power capacity to mission critical loads. It satisfies the requirements of the latest servers and optimises IT investment. IUMUMPREMIUM PROTECTIONONPROTECTIONONCTION PREMIUM PROTECTION TRUE PLATINUM MODULAR 20–300kVA PSPM90KBPSPM120KPSPM180KPSPM120KBPSPM240K 5.7" LCD screen (standard) 10" touch screen LCD screen (optional)MODULAR PARTS MODEL DESCRIPTIONDIMENSION D x W x HWEIGHT (kg) PSPM203P/3P 20kVA/20kW UPS module650X440X132(3U)34 PSPM303P/3P 30kVA/30kW UPS module650X440X132(3U) 35 PSBD10/9Battery drawer includes 10 pcs of 12V 9Ah batteries735 X 107 X 15526 PSPM90KBPlatinum Modular 90kW frame with battery option1100X600X1475 (30U)675 PSPM120KBPlatinum Modular 120kW frame with battery option1100X600X2010 (42U)932 PSPM120KPlatinum Modular 120kW frame1100X600X1475 (30U)333 PSPM180KPlatinum Modular 180kW frame1100X600X1475 (30U)435 PSPM300KPlatinum Modular 300kW frame1100X600X2010 (42U)549 PSBB280/9Battery bank (30U). Includes 280pcs1100X600X1475 (30U)480 PSBB400/9Battery bank (42U). Includes 400pcs1100X600X2010 (42U)760 37 ENHANCED UPS PROTECTION | PLATINUM MODULAR CENTURION TOWER SELECTION GUIDE MODEL PLATINUM MODULAR 90kW PLATINUM MODULAR 120kW PLATINUM MODULAR 120kW PLATINUM MODULAR 180kW PLATINUM MODULAR 300kW Model Number PSPM90KBPSPM120KBPSPM120KPSPM180KPSPM300K Phase3 phase in / 3 phase out Max Cabinet Capacity90kW120kW120 or 80kW180 or 120kW300kW One Power Module Capacity30kVA / 30kW30kVA / 30kW or 20kVA / 20kW30kVA / 30kW Max. Power Module No.344610 Battery TypeBuilt in batteryExternal battery Max. Battery Drawers PSBD10/912 x PSBD10/9 (120 x 12V*9Ah) 20 x PSBD10/9 (200 x 12V*9Ah) ––– INPUT Nominal Voltage (Vac)3 x 380 / 400 / 415 (3Ph + N) Voltage Range305–478VAC at 100% load; 208–304VAC at <70% load Nominal Frequency50/60Hz (Auto sensing) Frequency Range40Hz–70Hz Input Power Factor> 0.99 at 100% load, >0.98 at 50% load Harmonic Distortion (THDi)< 3% @ 100% load OUTPUT Nominal voltage (VAC)3 x 380 / 400 / 415 (3Ph + N) Voltage Regulation (Steady state)± 1% Typical (balanced load); ± 2% Typical (unbalanced load) Voltage Regulation (Transient) ± 5% Typical Nominal Frequency50/60Hz Frequency Range (Synchronized range) 46Hz–54Hz or 56Hz–64Hz Overload Capability1 hour for 110%, 10 mins for 125%, 1 min for 150% and 200ms for >150% Harmonic Distortion1.5% THD (Linear Load); 4% THD (Non-linear Load) EfficiencyUp to 94.5% BATTERY/CHARGER Battery Options32pcs or 36pcs or 40pcs (configurable) Temperature CompensationYes Maximum Charging Current8A8A for 30KW, 6A for 20KW power module8A ENVIRONMENT Operation Temperature0–40ºC (Note: De-rate output PF. 30-35oC PF = 0.9. 36-40oC PF = 0.8) Relative Humidity0–95% non-condensing Altitude<1000m for Nominal power (Note: UPS output power must be de-rated by 1% per 100m above 1000m) IP ClassIP 20 MANAGEMENT RS232 / USB / Dry ContactsRS232 & USB Supports Windows, Linux and MAC / Dry contacts included Optional SNMPPower management from SNMP manager and web browser STANDARDS SafetyIEC/EN 60950-1; IEC/EN 62040-1 EMCIEC/EN 62040-2 Category C3 All specifications are subject to change without notice. Backup times are approximate and variances may occur.38 PLATINUM MODULAR E 20KW | 40KW| 60KW 30KW | 60KW| 90KW ENHANCED UPS PROTECTION | PLATINUM MODULAR E The Platinum Modular E UPS Range is designed with Australian conditions and requirements in mind. The technology is based on a tried and tested platform ensuring reliability and performance. The Platinum Modular E is designed to be used in a wide range of applications from data centres to manufacturing, hospitals, military and mining environments to name a few. It provides the best power solution for your critical equipment. HIGH EFFICIENCY ONLINE DOUBLE CONVERSION The Platinum Modular E utilises true online double conversion technology with an efficiency of up to 96%. This significantly reduces overall Total Cost of Ownership (TCO). HIGH SCALABILITY Digital Signal Processor (DSP) control provides an improved solution with high performance. Integrated with modular design and parallel technology, the Platinum Modular E simplifies future power expansion. UNITY OUTPUT POWER FACTOR Platinum Modular E delivers unity output power (kVA=kW) providing the maximum power capacity to mission critical loads. It satisfies the requirements of the latest servers and optimises IT investment. MODULAR DESIGN Modular design is applied in power module, static switch module and battery module. This simplifies maintenance and replacement with low Mean Time To Repair (MTTR). As a result of modular design the Mean Time Between Failure (MTBF) is significantly increased. FEATURES FLEXIBLE BATTERY CONFIGURATION Allows for options of 32, 36 or 40 batteries per string. ADJUSTABLE CHARGING CURRENT Platinum Modular E provides maximum 6A for 20kW and 8A for 30kW charging current for every power module and it is adjustable based on requirement. HIGH OVERLOAD CAPABILITY Platinum Modular E supports 110% overload for 60 minutes, 125% for 10 minutes and 150% for 1 minute. GRAPHIC 5.7” SCREEN/MIMIC/LCD DISPLAY Designed for easy management, Platinum Modular E is equipped with a 5.7” graphic LCD screen. This interactive LCD display gives information on the unit’s operation, alarm and control. The LCD also includes an informative mimic display. N+1 PARALLEL REDUNDANCY Scalable architecture allows you to optimize cost expense to meet power demands by vertically expanding in a single rack enclosure from 20-60kW or 30-90kW and achieve N+1 redundancy in the same rack. IUMUMPREMIUM PROTECTIONONPROTECTIONONCTION PREMIUM PROTECTION TRUEPLATINUM MODULAR E MODELPLATINUM MODULAR E 20/40/60KWPLATINUM MODULAR E 30/60/90KW Model NumberPSPM90kEPSPM90kE Phase3 phase in / 3 phase out Capacity60kW90kW Max. Power Module No.3 INPUT Nominal voltage (Vac)3 x 380 / 400 / 415 (3Ph + N) Voltage Range305–478 VAC at 100% load; 208–478VAC at <70% load Nominal Frequency50/60Hz (Auto sensing) Frequency Range40Hz–70Hz Power Factor> 0.99 at 100% load, >0.98 at 50% load Harmonic Distortion (THDi)< 3% @ 100% load OUTPUT c Nominal voltage (Vac)3 x 380 / 400 / 415 (3Ph + N) Voltage Regulation (Steady state)± 1% Typical (balanced load); ± 2% Typical (unbalanced load) Voltage Regulation (Transient) ± 5% Typical Nominal Frequency50/60Hz Frequency Range (Synchronized range)46Hz–54Hz or 56Hz–64Hz Overload Capability1 hour for 110%, 10 mins for 125%, 1 min for 150% and 200ms for >150% Harmonic Distortion1.5% THD (Linear Load); 4% THD (Non-linear Load) EfficiencyUp to 94.5% BATTERY/CHARGERcc Battery Options32pcs or 36pcs or 40pcs (configurable) Temperature CompensationYes Maximum Charging Current6A per 20kW power module (User-adjustable); 8A per 30kW power module (User-adjustable) Battery Cabinet OptionsOptional – 15RU battery cabinet under UPS. Up to 120 pcs of 12V9Ah batteries ENVIRONMENTc Operation Temperature*0–40ºC Relative Humidity0–95% non-condensing Altitude**< 1000m for Nominal power IP ClassIP 20 MANAGEMENT c RS232 / USB Supports Windows, Linux and MAC Optional SNMPPower management from SNMP manager and web browser STANDARDS cc SafetyIEC/EN 60950-1; IEC/EN 62040-1 EMCIEC/EN 62040-2 Category C3 39 ENHANCED UPS PROTECTION | PLATINUM MODULAR E * When temperature is above 30º, the output power factor will be de-rated, 0.9 at 31oC–35ºC and 0.8 at 36ºC–40ºC. **If the UPS is installed or used in a place where the altitude is above 1000m, the output power must be derated by one percent per extra 100m. MODULAR PARTS MODELDESCRIPTIONDIMENSION D x W x H (mm)WEIGHT (kg) PSPM303P/3P 30KVA/30KW power module650x440x132(3U) 35 PSPM203P/3P 20KVA/20KW power module650x440x132(3U)34 PSPM90KEPlatinum Modular E UPS Frame 90kW I 1000 x 514 x 76080 PSPMBBOptional. Battery cabinet under UPS. 120 pcs of 12V9Ah batteriesII 1000 x 514 x 1370 100 I No modules. II Without batteries. PSPM20PSPM30Next >