PRODUCT CATALOGUESmooth power every day. Welcome to PowerShield, the premier power protection company in Oceania. As a fully Australian owned and operated company, we are committed to delivering consistent clean power to our customers through engineering excellence, exceptional support and a localised approach. Our purpose is to ensure smooth power every day, and we take pride in the built-in features of our products that provide flexibility and diversity in supporting all applications. At PowerShield, we prioritise customer service and constant improvement. Our focus is on providing the most reliable and economical protection against electrical disturbances for your valuable equipment. Our brand is trusted and well-known throughout Australia, with a diverse customer list that includes radio stations, government, defense, security, health and medical departments, mines, process control operations, point of sale, system integrators, and server room applications. Our Warehouses in both WA and NSW, together with our large distribution network of valued PowerShield partners throughout Oceania, ensures stock availability so that our products are always readily available to our customers. At PowerShield, we offer a variety of benefits to our customers, including priority stock allocations, special bid pricing, local representatives, training and support, and access to any relevant upgrades and information. We are committed to delivering the highest quality service and protection and we look forward to partnering with you to ensure consistent and reliable power for your valuable equipment.CHOOSE YOUR UPS UPS TypeStandby Power Systems have batteries that provide power only when AC power is lost and do not provide constant power. PowerShield provide a higher standard level of protection in all of our UPSs, which come with the next level of protection as standard – Line Interactive. Line-Interactive UPS Systems use Automatic Voltage Regulation (AVR) to correct abnormal voltages, without switching to battery. This means less drain on your backup power that can shorten the length of battery life. The UPS uses transformers to increase or decrease voltage and return it to an optimum range when the voltage reaches a preset low or high value. True Online Double Conversion (TODC) UPS Systems are a finely tuned method of voltage regulation. By continuously converting power from incoming AC to DC, then the DC to an ideal AC output, this double- conversion isolates equipment from all problems on the incoming line. TODC provides power with zero transfer time to the battery, making it ideal for sensitive equipment. SolutionsNinjaSafeGuard, Defender, Gladiator & Commander Range Centurion, Centurion Pro & Platinum Range Problems Addressed Power Failure refers to a complete mains power outage. This may be a result of damaged power lines, natural disasters, lightening strikes, grid overloads or car accidents. Power Sags refer to short term low voltage which may be a result of large loads starting up, utility switching or equipment failure. Power Surges refer to short term high voltage which can occur from a rapid reduction in loads and utility switching. Power Failure refers to a complete mains power outage. This may be a result of damaged power lines, natural disasters, lightening strikes, grid overloads or car accidents. Power Sags refer to short term low voltage which may be a result of large loads starting up, utility switching or equipment failure. Power Surges refer to short term high voltage which can occur from a rapid reduction in loads and utility switching. Brownouts are extended periods of reduced voltage. This can occur from heavy loads exceeding utility grid capacity and conservation of energy during peak demand periods. Spikes are an instant increase in voltage that can be in excess of 5000 volts. This is a result of lightening strikes sending voltage spikes down the power line. Line Noise is Radio Frequency Interference (RFI) and Electronic Magnetic Interference (EMI). This can be interference caused by transmitters, heavy machinery and large office machines. Frequency Drift is an intermittent change in frequency. This occurs when nearby generators are loaded and unloaded. Switching Transients are a quick high voltage increase that is shorter than a spike and result from indirect lightening strikes and utility switching. Harmonic Distortions are Pure Sign Wave deviation. They occur from transmissions from large machinery, computer and office equipment. Backup DurationShortShort to MediumLong Voltage Regulation On Battery OnlyLimitedPermanent Line Filtering (surges) LimitedLimitedPermanent Frequency Regulation NoNoYes Typical UsageSmall OfficeSmall Office / Entry Level EnterpriseHarsh Environment ProtectionLimitedMediumHigh BRONZE PROTECTIONOUR MINIMUM LEVEL OF PROTECTION THE ULTIMATE PROTECTION OF CRITICAL EQUIPMENT The Right UPS Solution We’ve made it simple. A Higher Standard Level of Protection. Power Shield offer a complete selection of power management and power protection solutions. From home computers to critical systems in high-availability environments, we have meticulously developed our products to provide better value and to suit the power needs of Australia and the Pacific region. CONTENTS 48 ACCESSORIES Accessories Maintenance Bypass Switches48 Unmanaged Power Distribution Units50 Managed Power Distribution Units52 Navigator Power Distribution Unit53 Cyber-Secure SNMP54 SNMP Cards56 Network Management Cards58 Automatic Transfer Switches60 Vertical Racks62 64 RUN CHART Run Chart – UPS Selection Guide64 40 SURGE PROTECTION AVR, Surge Protection & Filters ZapGuard ® Surge Protected Power Boards40 ZapGuard ® Pro Filters42 ZapGuard ® Pro Diverters44 VoltGuard AVR46 10 ENHANCED UPS PROTECTION Line Interactive SafeGuard UPS – 750–1000VA10 Defender UPS – 650–2000VA 12 Defender Rackmount UPS – 800VA14 Gladiator UPS 1500VA16 Commander Tower UPS – 1100–2000VA18 Commander RT UPS – 1100–3000VA20 PREMIUM UPS PROTECTION True Online Double Conversion Centurion Tower – 1000-10kVA22 Centurion RT 1000–3000VA26 Centurion RT 6000–10kVA28 Centurion RT LiFePO 4 1000–3000VA30 Centurion Tower 110V / 1000–3000VA32 Centurion Pro Series (Three Phase) 34 Platinum Modular (Three Phase)36 Platinum Modular E (Three Phase)38 22 8 BRONZE PROTECTION Standby Ninja Slimline UPS8 DC BACKUP Pilot DC UPSs Pilot DC 126 Pilot DC 367 66 DC UPS | PILOT DC MINI 12 The PowerShield DC Mini is designed to provide emergency power backup to all kinds of DC powered equipment including routers, modems (including fibre optic - ONT), VOIP phone systems, surveillance equipment, alarm systems and many critical telecommunications devices. The DC Mini can economically provide hours of operation during power failure. 12V PILOT DC MINI 12 FEATURES • Built in replaceable Li-ion battery • Auto start when plugged in • Embedded Micro-controller • Multi-colour indicator • Manual power off switch port • Overload, short-circuit, over-charge and over-discharge protection Power Connectors Included: Complete set of DC Power Jack tip adaptors allowing simple connection to all devices using DC powered jack sockets, such as modems, phones etc. PILOT DC SPECIFICATIONS MODEL PILOT DC MINI 12 Model Number PSDCMINI12–18 INPUT Voltage Range 90–26VAC Frequency Range 50Hz or 60Hz Surge Protection125Joules / 4500A OUTPUT Output Voltage 12V DC ± 5% Maximum Power18W (1.5A) BATTERY Battery TypeLithium-ion Battery / 3.7V DC / 2600mAh Typical Charging Time3 hours recover to 90% capacity PROTECTION BatteryDeep discharge, over-charge and short circuit protection Input/Output Short circuit and overload protection INDICATORS Multi-colour LED Display Full BatteryGreen – Solid Battery ChargingGreen – Slow Flashing Battery DischargingGreen – Quick Flashing FaultRed – Solid PHYSICAL Dimension D x W x H (mm) 78 x 42 x 74 Net Weight (g) 280 TYPICAL DEVICE BACKUP TIMES Typical Small Router (0.25 Amp / 3 Watt)150 minutes Typical Router (0.75 Amp / 9 Watt)120 minutesPILOT DC SPECIFICATIONS MODEL PILOT DC MINI 36 Model Number PSDCM36 INPUT Voltage DC12V–24VDC OUTPUT Voltage 12V / 15V / 19V / 24V Auto Detection Current36W = 3A / 2.4A / 1.89A / 1.5A ProtectionShort circuit protection, overload protection, over current protection, over voltage protection, over charging, over discharging BATTERY Battery TypeLithium-ion 18650 type battery (4 x 2600mAh) Voltage7.4V Capacity5200mAh ProtectionOvercharge protection, over discharge protection, over current, over voltage Backup Time36W = Full 20 minutes / 18W Half 60 minutes INDICATORS LEDON Green, Battery Yellow, Fault Red OUTPUT CONNECTORS Output CordDC Power Cord + Terminal Included Connector (Total: pieces)F5.5mm x 2.5mm / M5.5mm x 2.1mm & F5.5mm x 2.1mm / M5.5mm x 2.5mm F4.8mm x 1.7mm / M5.5mm x 2.1mm & F5.5 x 2.1mm / M4.8mm x 1.7mm F3.5mm x 1.35mm / M5.5mm x 2.1mm & F5.5 x 2.1mm / M3.5mm x 1.35mm PHYSICAL Dimension D x W x H (mm) 105 x 80 x 43 Net Weight (g) .320 ENVIRONMENT Humidity0% to 95% Non-condensing Operating Temperature0ºC–40ºC TYPICAL DEVICE BACKUP TIMES Small Router (6 Watts)24 hours Medium Router (12 Watts)12 hours 7 DC UPS | PILOT DC MINI 36 The PowerShield DC Mini 36 is an inline DC UPS designed to provide emergency power backup to DC powered equipment including modems, routers, VOIP phones, surveillance equipment, alarm systems and many critical telecommunication devices. FEATURES •Includes 4 x Li-Ion batteries •Auto-start when plugged in •Microprocessor control •Multicolour LED indicator and manual Power Off Switch Power Connectors Included: Complete set of DC Power Jack tip adaptors allowing simple connection to all devices using DC plugpacks. 12V | 15V |19V |24V PILOT DC MINI 36 •Overload, short circuit, overcharge and overdischarge protection •Long backup time •Additional terminal output for hardwired DC connection (Not included) (Not included)NINJA SLIMLINE UPS 8 BRONZE PROTECTION | NINJA SLIMLINE UPS Even the smallest disruption in power can affect valuable equipment and send an electrical system into reboot, often necessitating a technician to provide support. The Ninja Slimline UPS will ensure constant, uninterrupted power to not only protect equipment and extend its lifespan, but avoid unnecessary reboot glitches and costs. Designed for Australian conditions the Ninja Slimline UPS features Lithium Iron-Phosphate (LiFePO 4 ) battery technology to allow the UPS to operate continuously at up to 50ºC without reduction in battery life. With its ultra-thin design the Ninja Slimline UPS is designed for environments where space is limited and perfect for use in protecting equipment such as electrical boards, irrigation and reticulation panels, switchboards, intelligent homes, lightboards, menuboards and anywhere else that requires a compact power solution. 600VA FEATURES LONG LIFE BATTERY LiFePO 4 batteries offer up to 10 years of protection. SILENT OPERATION The Ninja Slimline UPS has been designed for optimum efficiency, ensuring a silent, stealthy solution for any environment. AUTO RESTART WHEN AC RECOVERS After an extended power outage the UPS will turn back on and resume equipment functionality once power has returned. HIGH EFFICIENCY Fanless design increases efficiency, saving power and reducing heat output. MOUNTING BRACKETS Mount the UPS vertically on walls, and inside electrical panels on a DIN rail mount. 5 YEAR WARRANTY With the benefit of LiFePO 4 battery technology the Ninja Slimline UPS comes with 5-year electronics and battery warranty. 4 Optional external Web/SNMP card for remote monitoring. Optional Environmental Monitoring Device to monitor temperature and humidity.LOAD PER CENT10%20%30%40%50%60%70%80%90%100% WATTS 3672108144180216252288324360 DISCHARGE TIME MIN 72302516151211976 NINJA SLIMLINE SPECIFICATIONS MODEL NINJA SLIMLINE 600 Model Number PSLN600 Capacity 600VA / 360W Topology Stand by INPUT Voltage220–240VAC Voltage Range180–270VAC Frequency Range 50Hz (auto sensing) OUTPUT Output Voltage 240VAC ± 10% Frequency 50Hz Transfer Time 6ms (Typical) Waveform (Batt. Mode) Simulated Sine Wave Outlets – UPS & Surge Protection 2 x IEC BATTERY Battery Type & Number 1 x Lithium Iron Phosphate (LiFePO 4 ), 4S4P, 18650 cells, 4400mAh Typical Recharge Time 4–8 hours recover to 90% capacity PROTECTION Full Protection Overload, discharge, thermal, short circuit and overcharge protection Surge Protection 760Joules / 5000Amps COMMUNICATIONS & MANAGEMENT Interface – Standard CommunicationsRS-232 port provides communication & power for optional web card Interface – Web/SNMP Card OptionPSECMB – External Web/SNMP card for UPS monitoring Environmental Monitoring Device Option PSEMD – for temperature and humidity monitoring, requires Web/SNMP card option SoftwareNetGuard® supports – Windows®, Linux, Unix and Mac (Free Download) PHYSICAL Dimension L x W x H (mm) 277 x 210 x 42mm (UPS only) Net Weight (kgs) 2.5 OPERATING ENVIRONMENT Temperature 0–50°C Humidity 0–90% RH (non-condensing) Noise LevelLess than 40dB COMPLIANCE Safety/EMCLVD EN62040-1, EMC EN62040-2, UN38.3 RoHS Directive 2011/65/EU WARRANTY Standard Warranty5-year electronic, 5-year battery warranty Product specifications are subject to change without prior notice. 9 BRONZE PROTECTION | NINJA SLIMLINE UPS 277mm 42mm 210mmNext >