< Previous20 COMMANDER RT 1100VA | 2000VA | 3000VA ENHANCED UPS PROTECTION | COMMANDER RT The Microprocessor-based, line Interactive, Pure Sine Wave Commander Rackmount/Tower UPS offers power protection for applications such as networking, telecom, security and motors. The Advanced ECO mode function allows cost effective operation of the UPS with an efficiency as high as 98%. To provide longer backup time the 2kVA and 3kVA models are expandable to include an additional battery bank. EXCEPTIONAL SURGE PROTECTION Offering the best surge protection in its class to protect against damaging surges. OUTPUT POWER FACTOR 0.9 The Commander RT is high-density UPS with output power factor 0.9 to provide higher performance and efficiency to critical applications. INFORMATIVE & EASY-SHIFT LCD DISPLAY The front panel LCD display panel is readily viewable whether the UPS is horizontal or vertical. It displays all critical and noncritical parameters, including the estimated battery backup time remaining. RACK/TOWER DESIGN The Commander RT can be easily installed as a floor-standing tower or in a 19-inch rack. PROGRAMMABLE OUTLETS This UPS comes with programmable power management outlets allowing the user to control the load segments, thereby extending battery backup times to mission critical devices by shutting down non-critical items. EMERGENCY POWER OFF FUNCTION (EPO) This feature can turn off and isolate the UPS in the event of fires or other emergencies. ECO & ADVANCED ECO MODE It has an advanced ECO mode, which allows the UPS to operate at a very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode. FEATURES HID COMMUNICATION VIA USB HID can be used for simple management with Windows, Apple, Linux and NAS devices and a large variety of industrial controllers that support HID. HID ensures a safe and orderly shutdown in the event of a prolonged power outage. NETGUARD SOFTWARE COMMUNICATION VIA USB The free, downloadable NetGuard software provides complete power monitoring. Parameters such as input/output voltage, battery capacity and load level are easily viewed. It also ensures a safe and orderly shutdown in the event of a prolonged outage. HOT SWAPPABLE BATTERIES Incorporates hot-swappable internal battery packs which can be accessed via the front panel for maintenance changes, keeping the UPS operational during battery replacement. Additional battery banks can be added to increase battery backup time. BUCK AND BOOST AVR Built-in buck and boost AVR (combination of Australian and IEC). OPTIONAL ACCESSORIES: •PSSNMP – SNMP card (option to connect a PSEMD) •PSEMD – Environmental Monitoring Device for temperature and humidity •PSModbus - Modbus card •PSAS400 – AS400 dry contact card •PSRK - 1RU rail kit •PSRTBB8, PSRTBB12 – Extra battery bank •PSMBS2k, PSMBS3k – Maintenance Bypass Switch ENHAEDCEANCENHANCEDNCENHANC CTIONONONCTIONPROTECTIOPROTECTION ENHANCED PROTECTION INTERACTIVEINT INTERACTIVE DDDDDDDDDD21 ENHANCED UPS PROTECTION | COMMANDER RT COMMANDER RT SELECTION GUIDE MODEL COMMANDER RT 1100K COMMANDER RT 2000K COMMANDER RT 3000K RT BATTERY BANKS Model Number PSCRT1100PSCRT2000PSCRT3000PSCRTBB8PSCRTBB12 Capacity 1100VA/990W2000VA/1800W3000VA/2700WSuits PSCRT2000Suits PSCRT3000 Topology Line Interactive, Pure Sine Wave INPUT Voltage240VAC (Nominal) Voltage Range162–290VAC Frequency Range50/60 Hz (Auto Sensing) ±5Hz OUTPUT Output Voltage (AC Mode)240VAC (Selectable200/208/220/230VAC) ±10% AVR Voltage Regulation (Batt. Mode)±3% Frequency Range (Batt. Mode)50Hz or 60Hz ± 1Hz Current Crest Ratio3:1 Transfer Time6ms (Typical) Waveform (Batt. Mode)Pure Sine Wave IEC Outlets10A, C13 x 510A, C13 x 5 15A, C19 x 1 Australian Sockets32 EFFICIENCY ECO Mode (Advanced)98%98%98% Battery Mode90%91%92% BATTERY Standard Model Battery Type & Number12V*9Ah (x 2)12V*9Ah (x 4)12V*9Ah (x 6)12V*9Ah (x 8)12V*9Ah (x 12) Typical Recharge Time4 Hours Recover to 90% Capacity Additional Battery BanksN/APSCRTBB8 (x1)PSCRTBB12 (x1) PROTECTION Full Protection Overload, thermal, short circuit, discharge and overcharge protection Surge Protection 1560Joules / 32500Amps COMMUNCATIONS & MANAGEMENT InterfaceUSB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry contact SoftwarePowerShield® NetGuard® software supports Windows®, Linux, Unix, and MAC HIDSupports Windows, Apple, Linux, NAS and various industrial controllers LCD Display/AlarmAC mode, Batt. mode, Load Level, Input Voltage, Output Voltage, Overload, Fault, Low Batt., Batt. Time remaining Audible AlarmBattery mode, low battery (batt. mode), fault, overload PHYSICAL Dimension L x W x H (mm) (380 x 438 x 88)(480 x 438 x 88)(600 x 438 x 88)(480 x 438 x 88)(600 x 438 x 88) Weight Net/Gross (kg)(15 / 16kg)(23kg / 25kg) (32kg / 35kg)(25kg / 27kg)(35kg / 37kg) OPERATING ENVIRONMENT Temparature0–40°C Humidity0–90% (RH Non-condensing) Humidity< 45dB COMPLIANCE Safety/EMCEN62040 - 1 - 1 2003, IEC60950 - 1 - 1, EN62040 - 2 2006 RoHS Directive 2011 / 65 / EU Specifications are subject to change without prior notice. Note: 3kVA models require a15 Amp wall socket. REAR VIEW PSCRT1100 | PSCRT2000PSCRT300022 CENTURION TOWER 1000VA | 2000VA | 3000VA | 6000VA | 10000VA ENHANCED UPS PROTECTION | CENTURION TOWER The Centurion is a True Online Double Conversion UPS designed to provide comprehensive power protection for critical equipment. Versatile software management and hardware options offer the flexibility to build up a power protection solution to fit any application. Meticulously developed by PowerShield engineers to be a world leading technology UPS, the Centurion Tower addresses absolutely all requirements and features as has been demanded by the sophisticated Australian power consumer and hence stands in a class of its own, as a world leading UPS technology. EXCEPTIONAL SURGE PROTECTION Offering the best protection in its class to protect against damaging surges. OUTPUT POWER FACTOR The Centurion Tower is a high-density UPS with output power factors of 0.9 for 1-3kVA models and 1.0 for 6-10kVA models, providing higher performance and efficiency to critical applications. INFORMATIVE LCD DISPLAY The front panel LCD display panel is readily viewable and displays all critical and noncritical parameters, including the estimated battery backup time remaining. PROGRAMMABLE OUTLETS This UPS comes with programmable power management outlets allowing the user to control the load segments, thereby extending battery backup times to mission critical devices by shutting down non-critical items. EMERGENCY POWER OFF FUNCTION (EPO) This feature can turn off and isolate the UPS in the event of fires or other emergencies. ADVANCED ECO MODE It has an advanced ECO mode, which allows the UPS to operate at a very high efficiency, up to 98%. FEATURES HID COMMUNICATION VIA USB HID can be used for simple management with Windows, Apple, Linux and NAS devices and a large variety of industrial controllers that support HID. HID can also be used for safe and orderly shutdown. NETGUARD SOFTWARE COMMUNICATION VIA USB The free, downloadable NetGuard software provides complete power monitoring. Parameters such as input/output voltage, battery capacity and load level are easily viewed. It also ensures a safe and orderly shutdown in the event of a prolonged outage. BATTERY BANK EXTENSION OPTIONS The Centurion Tower provides the option to increase battery backup time by simply adding additional battery banks. To address the need for fast charging of multiple battery banks, PowerShield engineers have incorporated additional independent internal chargers into the PSCEBB18CH and PSCEBB60CH. OPTIONAL ACCESSORIES •PSSNMPV4 – SNMP card (option to connect a PSEMD) •PSEMD – Environmental Monitoring Device •PSModbus – Modbus card •PSAS400 – AS400 dry contact card •N+X parallel redundancy available for 6K/10K models •Battery Banks – Backup time for all models is easily extended by simply plugging additional battery banks PSCEBB6, PSCEBB12, PSCEBB18CH, PSCEBB40, PSCEBB60CH •External Maintenance Bypass Switches – PSMBS2k, PSMBS3k, PSMBSWPB6k, PSMBSWPB10k IUMUMPREMIUM PROTECTIONONPROTECTIONONCTION PREMIUM PROTECTION TRUE REAR VIEW PSCE1000 PSCE2000PSCE3000 PSCE6000PSCE10KCENTURION TOWER SELECTION GUIDE MODEL CENTURION TOWER 1K CENTURION TOWER 2K CENTURION TOWER 3K CENTURION TOWER 6K CENTURION TOWER 10K Model Number PSCE1000 (L)PSCE2000 (L)PSCE3000 (L)PSCE6000 (L)PSCE10K (L) Capacity 1000VA / 900W2000VA / 1800W3000VA / 2700W6000VA / 6000W10000VA / 10000W Topology True online double-conversion INPUT Nominal Voltage200 / 208 / 220 / 230 / 240VAC208 / 220 / 230 / 240VAC Voltage Range110–300VAC ± 5% at 50% load 160–300VAC ± 5% at 100% load 110–300VAC at 50% load 176–300VAC at 100% load Frequency Range40Hz–70Hz46Hz–54Hz or 56Hz–64Hz Input Power Factor Correction≥ 0.99 @ 100% load OUTPUT Output Voltage240VAC (200 / 208 / 220 / 230 / 240VAC – Selectable)240VAC (208 / 220 / 230 / 240VAC – Selectable) Frequency Range (Synchronized Range)47–53Hz or 57–63Hz (Auto detect)46–54Hz or 56–64Hz (Auto detect) Frequency Range (Batt. Mode)50Hz ± 0.1Hz or 60Hz ± 0.1Hz Voltage Regulation± 1% Current Crest Ratio3:1 Harmonic Distortion > 2% THD (linear load) : > 4% THD (non-linear load)> 3% THD (linear Load) > 6% THD (non-linear Load) Transfer Time AC Mode to Batt. Mode Zero Inverter to Bypass4ms (typical)Zero Waveform (Batt. Mode)Pure Sinewave IEC Outlets10A, C13 x 210A, C13 x 215A, C19 x 110A, C13 x 2 Australian Sockets244Hard wired terminal input / output EFFICIENCY AC Mode90%91%94%94% ECO Mode98%98% Battery Mode89%90%92%92% BATTERY Standard Battery Type12V*9AH(x3)12V*9AH(x6)12V*9AH(x6)12V*9AH(x20)12V*9AH(x20) Typical Recharge Time 4 hours recover to 90% capacity7 hours recover to 90% capacity Charging Current (max)1.5A4A Long Run Charging Current (max)1A / 2A / 4A / 6A / 8A (selectable via LCD setting)4.0A Charging Voltage (nominal) 36VDC72VDC240VDC PROTECTION Full Protection 1248 Joules / 39000Amps1080 Joules / 30000Amps COMMUNICATIONS & MANAGEMENT InterfaceUSB and RS232 as standard. Intelligent slot for PSSNMPV4 or PSAS400 dry contact or PSMBUS SoftwarePower Shield Netguard® Software - supports Windows based operating Systems, Linux, Unix & Mac HIDSupports Windows, Apple, Linux, NAS and various industrial controllers LCD Display/AlarmUPS Status, Load Level, Battery Level, Input/Output Voltage, Battery Time Remaining and Fault Indicators Audible AlarmBattery Mode, Low Battery, Overload, Fault PHYSICAL Standard Dimensions D x W x H (mm)396 x 145 x 240425 x 190 x 335592 x 250 x 576 Weight (kg)12.525.8277578 Long-run Dimensions D x W x H (mm) 396 x 145 x 240425 x 190 x 335592 x 250 x 576 Weight (kg)5.81213.82325 OPERATING ENVIRONMENT Humidity x Temperature20–95% (RH non-condensing) @ 0–40°C Noise LevelLess than 50dBA @ 1metreLess than 55dB @ 1metre COMPLIANCE Safety/EMCEN62040 - 1 - 1 2003, IEC60950 - 1 - 1, EN62040 - 2 2006 RoHS Directive 2001 / 65 / EU 23 ENHANCED UPS PROTECTION | CENTURION TOWER Specifications are subject to change without prior notice. Long run models are available with larger chargers (no internal batteries). 3kVA models require a 16 Amp wall socket.24 ENHANCED UPS PROTECTION | CENTURION TOWER While unlimited numbers of batteries banks can be added, if large battery banks are installed and require fast charging it is recommended to add a battery bank that has an internal charger. Usually these should be added as the second, third or fourth battery bank depending on your requirements. The PSCEBB18CH and PSCEBB60CH battery banks have built-in chargers and more batteries than regular battery banks. PSCEBB18CH suits 2k & 3K. PSCEBB60CH suits 6k & 10K. CENTURION TOWER LOAD VA VALOADPSCE1000PSCEBB6PSCEBB6PSCEBB6 1000VA100%13 minutes52 minutes97 minutes125 minutes 500VA50%26 minutes104 minutes194 minutes250 minutes VALOADPSCE2000PSCEBB12PSCEBB18CHPSCEBB12 2000VA100%13 minutes52 minutes110 minutes150 minutes 1000VA50%26 minutes104 minutes220 minutes300 minutes VALOADPSCE3000PSCEBB12PSCEBB18CHPSCEBB12 3000VA100%5 minutes27 minutes62 minutes100 minutes 1500VA50%10 minutes54 minutes124 minutes200 minutes VALOADPSCE6000PSCEBB40PSCEBB60CHPSCEBB40 6000VA100%10 minutes55 minutes116 minutes170 minutes 3000VA50%28 minutes110 minutes232 minutes340 minutes VALOADPSCE10KPSCEBB40PSCEBB60CHPSCEBB40 10KVA100%5 minutes28 minutes75 minutes100 minutes 5000VA50%10 minutes56 minutes150 minutes200 minutes TOWER MODELS BATTERY BANKS MODEL NUMBERPSCEBB6PSCEBB12PSCEBB18CHPSCEBB40PSCEBB60CH Suits UPSPSCE1000PSCE2000 / 3000PSCE2000 / 3000PSCE6000 / 10k / 20kPSCE6000 / 10k / 20k BATTERY Type12V*9AH Charging Voltage (Nominal DC)36Vdc72Vdc72Vdc240Vdc240Vdc ChargerFrom UPSFrom UPS4AmpsFrom UPS4Amps PHYSICAL Dimensions D x W x H (mm)396 x145 x 240mm425 x 190 x 335mm 534 x 190 x 335mm 592 x 250 x 576mm592 x 250 x 826mm Weight Net/Gross (kg)20 / 2140 / 4260 / 63122 / 138180 / 198 PROTECTIONDC Circuit BreakerFuses Virtually unlimited run times can be achieved by adding battery banks to standard models. + + + + + + + + + + + + + + +SLIM BUILD, GIANT POSSIBILITIES NINJA SLIMLINE UPS Designed for Australian conditions, the Ninja Slimline UPS features Lithium Iron-Phosphate (LiFePO 4 ) battery technology to allow the UPS to operate continuously at up to 50ºC without reduction in battery life. With its ultra-thin design the Ninja Slimline UPS is designed for environments where space is limited and perfect for use in protecting equipment such as electrical boards, irrigation and reticulation panels, switchboards, intelligent homes, lightboards, menuboards and anywhere else that requires a compact power solution. 42mm 210mm277mm Space saving design Long life lithium batteries Limitless applications26 CENTURION RT 1000VA | 2000VA | 3000VA ENHANCED UPS PROTECTION | CENTURION RT The Centurion RT features true online double conversion. As our highest single phase power density UPS, this sophisticated range will provide the most comprehensive protection for mission critical devices such as sensitive networks, computers, servers, telecom applications, as well as industrial applications. Meticulously developed by PowerShield engineers to be a world leading technology UPS, the Centurion RT addresses absolutely all requirements and features as has been demanded by the sophisticated Australian power consumer and hence stands in a class of its own, as a world leading UPS technology. EXCEPTIONAL SURGE PROTECTION Offering the best surge protection in its class to protect against damaging surges. OUTPUT POWER FACTOR The Centurion RT is high-density UPS with output power factor (PF = 0.9) to provide higher performance and efficiency to critical applications. INFORMATIVE & EASY-SHIFT LCD DISPLAY The front panel LCD display panel is readily viewable whether the UPS is horizontal or vertical. It displays all critical and noncritical parameters, including remaining battery backup time. RACK/TOWER DESIGN The Centurion RT can be easily installed as a floor-standing tower or in a 19-inch rack. PROGRAMMABLE OUTLETS This UPS comes with programmable power management outlets allowing the user to control the load segments, thereby extending battery backup times to mission critical devices by shutting down non-critical items. EMERGENCY POWER OFF FUNCTION (EPO) This feature can turn off and isolate the UPS in the event of fires or other emergencies. ECO & ADVANCED ECO MODE It has an advanced ECO mode, which allows the UPS to operate at a very high efficiency, up to 98%. EXPANDABLE BACKUP TIME Increase backup time by adding external battery banks. FEATURES HID COMMUNICATION VIA USB HID can be used for simple management with Windows, Apple, Linux and NAS devices and a large variety of industrial controllers that support HID. HID can also be used for safe and orderly shutdown. NETGUARD SOFTWARE COMMUNICATION VIA USB The free, downloadable NetGuard software provides complete power monitoring. Parameters such as input/output voltage, battery capacity and load level are easily viewed. It also ensures a safe and orderly shutdown in the event of a prolonged outage. HOT SWAPPABLE BATTERIES Battery banks are hot-swappable. This keeps the UPS operational during battery replacement. STANDARD EXTRA LARGE CHARGER The Centurion RT comes with a larger charger than other UPSs ensuring rapid recharge times. OPTIONAL ACCESSORIES •PSSNMPV4 – SNMP card (option to connect a PSEMD) •PSEMD – Environmental Monitoring Device for temperature humidity •PSModbus – Modbus card •PSAS400 – AS400 dry contact card •PSRK – 1RU rail kit •PSRTBB6, PSRTBB8, PSRTBB12 – Extra battery bank •PSMBS2k, PSMBS3k – Maintenance Bypass Switches IUMUMPREMIUM PROTECTIONONPROTECTIONONCTION PREMIUM PROTECTION TRUE Centurion RT 1000 (L) 10Amp IEC input socket REAR VIEW Centurion RT 2000/2000SB 10Amp IEC input socketBattery Bank PSRTBB6 Centurion RT 2000 (L) 16Amp IEC input socketCenturion RT 3000 (L) 16Amp IEC input socketBattery Bank PSRTBB12CENTURION RT RANGE TOWER SELECTION GUIDE MODEL CENTURION RT 1KVA & 1KVA (L) CENTURION RT 2KVA (SB) CENTURION RT 2KVA & 2KVA (L) CENTURION RT 3KVA & 3KVA (L) RT BATTERY BANKS Model NumberPSCERT1000 / PSCERT1000L PSCERT2000SBPSCERT2000 / PSCERT2000L PSCERT3000 / PSCERT3000L PSRTBB6PSRTBB8PSRTBB12 Capacity1000VA/900W2000VA/1800W3000VA/2700WSuits PSCERT 1000 Suits PSCERT 2000SB Suits PSCERT2000/ PSCERT3000 TopologyTrue online double-conversion, Pure Sine Wave INPUT Voltage Range Low Line Transfer160VAC / 140VAC / 120 / 110VAC ± 5 % (based on load percentage 100%–80% / 80%–70% / 70%–60% / 60%–0) Low Line Comeback175VAC / 155VAC / 135VAC / 125VAC ± 5 % High Line Transfer300VAC ± 5 % High Line Comeback290VAC ± 5 % Frequency Range40Hz–70Hz PhaseSingle phase with ground Power Factor Correction 0.99 @ nominal voltage (100% load) OUTPUT Output Power Factor0.9 Output Voltage (AC Mode)240VAC (Selectable 200/208/220/230/240VAC) Voltage Regulation (Batt. Mode)± 1% Frequency Range (Batt. Mode)50Hz or 60Hz ±1Hz Current Crest Ratio3:1 (max.) Transfer AC Mode to Batt. ModeZero Inverter to Bypass4ms (Typical) Waveform (Batt. Mode)Pure Sine Wave IEC Outlets10A, C13 x 5 10A, C13 x 5 16A, C19 x 1 Australian Sockets32 EFFICIENCY ECO Mode (Advanced)96%97%97% Battery Mode86%87%87% BATTERY Battery Number (12 V*9AH)x 3x 4x 6x 6x 6x 8x 12 Typical Recharge Time4 hours recover to 90% capacity (for standard model only) Charging Current (max.) Standard Models – 1.5Amp. Long Run Models – 1Amp / 2Amp / 4Amp / 6Amp selectable (factory default is 6Amp) PROTECTION Full Protection Overload, discharge, thermal, short circuit and overcharge protection Surge Protection984 Joules / 22000 Amps COMMUNICATIONS AND MANAGEMENT InterfaceUSB or RS232 as standard, Intelligent slot for PSSNMP, PSModbus or PSAS400 dry con-tact SoftwarePowerShield® NetGuard® software – supports Windows, Linux, Unix and Mac based operating systems HIDSupports Windows, Apple, Linux, NAS and various industrial controllers LCD Display/AlarmUPS Status, Load & Battery Level, Input/Output Voltage, Batt. Time Remaining and Fault Indicators Audible AlarmBattery Mode, Bypass Mode, Low Battery (Batt. Mode), Fault, Overload PHYSICAL Dimensions (D x W x H) mm380 x 438 x 88480 x 438 x 88600 x 438 x 88600 x 438 x 88 480 x 438 x 88 480 x 440 x 88 600 x 438 x 88 Weight (kg)15.28.419.525.610.526.811.624.829.142 OPERATING ENVIRONMENT Temperature0–40°C Humidity20–90% (RH Non-condensing) Noise Level< 50dBA @ 1 Meter COMPLIANCE Safety / EMC / RoHSEN62040-1-1 2003, IEC60950-1-1 / EN62040-2 2006 / Directive 2011/65/EU 27 ENHANCED UPS PROTECTION | CENTURION RT Specifications are subject to change without prior notice. Models ending in ‘L’ are long run models with larger chargers and therefore have no internal batteries Centurion 2000L and 3kVA models require a 16 Amp wall socket.28 CENTURION RT 6000VA | 10kVA ENHANCED UPS PROTECTION | CENTURION RT The Centurion RT features true online double conversion. As our highest single phase power density UPS, this sophisticated range will provide the most comprehensive protection for mission critical devices such as sensitive networks, computers, servers, telecom applications, as well as industrial applications. Meticulously developed by PowerShield engineers to be a world leading technology UPS, the Centurion RT addresses absolutely all requirements and features as has been demanded by the sophisticated Australian power consumer and hence stands in a class of its own, as a world leading UPS technology. EXCEPTIONAL SURGE PROTECTION Offering the best surge protection in its class to protect against damaging surges. UNITY OUTPUT POWER FACTOR (PF=1) The Centurion RT is a high-density UPS with unity output power factor (PF=1) to provide higher performance and efficiency to critical applications. INFORMATIVE & EASY-SHIFT LCD DISPLAY The front panel LCD display panel is readily viewable whether the UPS is horizontal or vertical, displaying all critical & non-critical parameters, including remaining battery backup time. RACK/TOWER DESIGN The Centurion RT can be easily installed as a floor-standing tower or in a 19-inch rack. High power density means that both the UPS and the battery bank are only 2RU height each. EMERGENCY POWER OFF FUNCTION (EPO) This feature can turn off and isolate the UPS in the event of fires or other emergencies ECO & ADVANCED ECO MODE It has an advanced ECO mode, which allows the UPS to operate at a very high efficiency, up to 98%. When the utility mains input voltage is within the ECO range the UPS saves energy by passing the mains supply directly through to the load, while the inverter continues to operate in a passive mode HOT SWAPPABLE BATTERIES Battery banks are hot-swappable, keeping the UPS operational during battery replacement. Additional battery banks can be added to increase battery backup time. FEATURES HID COMMUNICATION VIA USB HID can be used for simple management with Windows, Apple, Linux and NAS devices and a large variety of industrial controllers that support HID. HID ensures a safe and orderly shutdown in the event of a prolonged power outage. NETGUARD SOFTWARE COMMUNICATION VIA USB The free, downloadable NetGuard software provides complete power monitoring. Parameters such as input/output voltage, battery capacity and load level are easily viewed. It also ensures a safe and orderly shutdown in the event of a prolonged outage. STANDARD EXTRA LARGE CHARGER The Centurion RT has been designed with a larger charger than other UPSs ensuring rapid recharge times when adding additional battery banks. Larger charger allows for easy addition of extra battery banks OPTIONAL ACCESSORIES •PSSNMPV4 – NMP card (option to connect a PSEMD) •PSEMD – Environmental Monitoring Device for temperature and humidity •PSModbus – Modbus card •PSAS400 – AS400 dry contact card •PSRK – 1RU rail kit •PSRTBB16, PSCERBB20 – Extra battery modules •PSMBSR10K – Maintenance Bypass Switches •PSPDU10K – 10KVA PDU with 10A IEC 320 C13 (x8), 16A IEC 320 C19 (x4) IUMUMPREMIUM PROTECTIONONPROTECTIONONCTION PREMIUM PROTECTION TRUECENTURION RT RANGE (6K–10K) MODEL CENTURION RT 6000LCENTURION RT 10KLSTANDARD RT BATTERY BANK OPTIONAL RACK BATTERY BANK Model NumberPSCERT6000LPSCERT10KLPSRTBB16PSCERBB20 Capacity6000VA/6000W10kVA/10kW Suits PSCERT6000L & PSCERT10KL TopologyTrue online double-conversion, Pure Sine Wave INPUT Voltage Range Line Loss110–300Vac @ (0–60%) Load; 140–300V @ (60–80%) Load; 176–300VAC @ (80–100%) Load Low Line ComebackLow Line Loss Voltage + 10V High Line ComebackHigh Line Loss Voltage – 10V Frequency Range46Hz–54 Hz @ 50Hz system; 56Hz–64 Hz @ 60Hz system PhaseSingle phase with ground Input Power Factor Correction 0.99 @ nominal voltage (100% load) OUTPUT Output Voltage240VAC (Selectable 208 / 220 / 230 / 240VAC) AC Voltage Regulation± 1% Frequency Range (Synchronized Range) 46Hz–54 Hz @ 50Hz system 56Hz–64 Hz @ 60Hz system Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz Overload AC Mode100%–110%: 10min ; 110%–130%: 1min ; >130% : 1sec Battery Mode100%–110%: 30sec ; 110%–130%: 10sec ; >130% : 1sec Current Crest Ration3:1 Max Harmonic Distortion 1 % @ 100% Linear Load; 4% @ 100% Non-linear Load Transfer Time Line to Battery0 ms Inverter to Bypass0 ms Inverter to Eco< 10 ms OutletsHard wired terminal input / output. IEC outlets with PSPDU10K PDU. EFFICIENCY AC Mode> 94% Battery Mode> 93% BATTERY Battery BanksPSRTBB16 (standard), PSCERBB20 (optional). Customised options available Battery NumberBatteries are 12Vdc. Customised optional strings of 16, 18, 20x 16x 20 Typical Recharge Time4 hours for PSRTBB16 and PSCERBB20 Charging Current (max.)4 A ± 10% COMMUNICATIONS AND MANAGEMENT InterfaceUSB and RS232 as standard Software PowerShield® NetGuard® software – supports Windows, Linux, Unix and Mac based operating systems HIDSupports Windows, Apple, Linux, NAS and various industrial controllers OptionalIntelligent slot for PSSNMPV4, PSModbus or PSAS400 dry contact PHYSICAL Dimension, (D x W x H) mm Weight (kg) UPS Unit: 655 x 438 x 88 [2U] 17kgUPS Unit: 655 x 438 x 88 [2U] 20kg733 x 438 x 88 [2U] 580 x 438 x 133 [3U] Weight (kg)13.5165457 OPERATING ENVIRONMENT Temperature0–40°C Humidity95% (RH Non-condensing) Altitude< 1000m Noise Level < 55dB @ 1 Meter < 58dB @ 1 Meter 29 ENHANCED UPS PROTECTION | CENTURION RT Product specifications are subject to change without notice. Derate capacity to 60% in CVCF mode. Derate capacity to 90% when the output voltage is adjusted to 208VAC. If the UPS is installed or used in a place where the altitude is above 1000m, the output power must be derated one percent per 100m. Power Factor = 1 when using 20 battery string; Power Factor = 0.9 when using 18 battery string; Power Factor = 0.8 when using 16 battery string. REAR VIEW Rear PSCERT 6000L and 10KLRear Battery Pack PSRTBB16Next >